Insertion Test Spectrometer

Information
May 02, 2026

Rapid identification of unknown substances using Direct Insertion

In this study an efficient method for confident identification of unknown substances is described. The method uses the Direct Insertion Probe (DIP) coupled to a GC Orbitrap mass analyzer with both

Information
Jan 15, 2026

Workflow solutions for direct insertion, real-time gas

Direct insertion GC/MS is an easy-to-use screening technique, and offers fast analysis with GC separation and mass spectral confirmation in under a minute. Consumables supporting this

Information
May 24, 2026

Introduction to Mass Spectrometer Gas Chromatography

The Direct Insertion Probe (DIP) is used to introduce less volatile samples into the ion source of the mass spectrometer. It consists of a long rod with a sample holder on the tip.

Information
Jun 03, 2026

General Chapters: <736> MASS SPECTROMETRY

For volatilizable solids, the most frequently used method of sample introduction is the direct insertion probe. Here, the sample is placed in a small crucible at the tip of the probe, which is heated under

Information
Nov 23, 2025

TITLE OF PAPER

We reviewed the pros and cons of using insertion probes vs. using slipstreams for reaction and process monitoring by IR spectrometric techniques. Not unexpectedly, we conclude that each approach has

Information
Mar 29, 2026

Direct Insertion Probe Data Sheet

The Direct Insertion Probe (DIP), also referred to as a solids probe, allows the user to introduce solid or liquid samples directly into the ion source, which is used to rapidly analyze solids or trace

Information
Aug 23, 2025

2.4: Direct Insertion Probe

The Direct Insertion Probe (DIP) is widely used to introduce low vapor pressure liquids and solids into the mass spectrometer. The sample is loaded into a short capillary tube at the end of a heated

Information
Jan 22, 2026

Direct sample insertion for inductively coupled plasma spectrometry

Direct sample insertion (DSI) is an alternative sample introduction technique for inductively coupled plasma spectrometry whereby the sample, either liquid or solid, is placed onto or into a

Information
Aug 24, 2025

Introduction to Mass Spectrometer Gas

The Direct Insertion Probe (DIP) is used to introduce less volatile samples into the ion source of the mass spectrometer. It consists of a long rod

Information
Sep 05, 2025

Direct Insertion Probe – Mass Spectrometry (DIP-MS) in the

Direct insertion probe–mass spectrometry (DIP-MS) is a new application that can characterize fuels, from crude oils to tar sands, without previous separation or treatment.